GP Series Frequency-LINE UPS (single-phase output)
UPS 8KVA ~ 30KVA (1Ph Out)
WARD GP11 series UPS is single Phase Input and Single Phase Output and the capacity from 8KVA to 20KVA; GP31 series UPS is three phases input & single phase output and the capacity is from 10KVA to 30KVA. They can use in parallel or separately against different request. They suitable for large machine room, data management center, manufacture industry, petrify system, metallurgical industry, power system etc. important area.
FEATURES
High Reliable
* Adopt twin change on line technology, sequester extraneous interference * Favorable overload ability and protection * Design with 100% unbalance protection * 100% Non linear load ability * IGBT, PWM inverter together with digital
logic power control technology
* Industrial grade UPS
Super Safety
* The output isolate transformer can avoid the destruction of abnormal signal & lightning stroke * With static bypass, repair bypass, battery maintain bypass * Cold start
Smart
* Different loading have different use way. Single UPS, 1+1 or N+1 etc. * Modular design, easy to repair * Intelligent management for battery pack
Economic
* The efficiency of complete system more than 90%, it will be up to 95% or more if ECO mode
Easy Operation
* LED/LCD display, it’s easy to operate
Intelligent
* It can remote management and TVSS through the offered RS232()RS422, optional SNMP Card, RJ45 etc. communicate port
APPLIANCE
* Data management equipment and system * Automatic control systems * Hospital * Mini office system * Telecommunication systems * Bank
TECHNICAL SPECIFICATIONS
Model
GP1108
GP1110
GP1115
GP1120
GP3110
GP3115
GP3120
GP3130
Capacity
8KVA
10KVA
15KVA
20KVA
10KVA
15KVA
20KVA
30KVA
Input
Voltage
220VAC±25% (Single phase 2 wires + G)
220/380VAC±20% (Three phases 4 wires + G)
Frequency
50Hz ± 10%
Power Factor
0.8 ( 0.95 if UPS with filter )
Output
Voltage
220VAC±1% (steady state)
220VAC±2% (steady state)
Frequency
Free synchronized to main (AC Power Mode); 50Hz±0.5%(Battery Mode)
Power Factor
0.8 (lagging)
Wave Form
Sine Wave
Distortion
£3% (linear load), £5% (non linear load)
Crest Factor
3:1
Transitory Voltage
220VAC ± 4%
220VAC ± 5%
Efficiency
³90%
Battery
Type
12VDC Sealed lead acid battery, maintenance free
Nominal Voltage
192VDC (16 PCS)
384VDC (32 PCS)
Backup Time
As per the request of customer
Recharge Time
7 ~ 10 hours up to 90% capacity
Charge Current
10~25A (Adjustable)
Transfer Time
0 ms ( AC to DC or DC to AC); < 4 ms (Bypass to Inverter or Inverter to Bypass)
LCD Display
UPS work situation, AC power situation, Battery situation, automatic turn to bypass, overload
Overload Ability
150% for 30 seconds, 125% for 10 minutes
Protection
Over Voltage, Under Voltage, Over Load, Over Temperature, Short Circuit, Lightning Stroke etc.
Alarm
Over Temperature, Battery, Bypass, AC Power Abnormal, Over Load, Over Voltage